| Sign In | Join Free | My futurenowinc.com |
|
MOQ : 5
Model Number : PF0030/PC
Brand Name : PF0030/PC
Packaging Details : -
Description : Power Entry Modules (PEM) RoHS
Stock : 383
A comprehensive range of quality mains rated inlets, outlets, and connectors conforming to IEC and EN 60320 specifications. These connectors carry UL, CSA, VDE, and other approvals, offering electrical ratings up to 20A and 250V (UL). They provide solutions for most mains powered equipment and cable applications.
The following tables detail various IEC connector types, their specifications, and available configurations.
| IEC Standard | Sheet No. | Mounting Style | Termination Types | Current Rating | Part Numbers (Examples) | Key Features |
|---|---|---|---|---|---|---|
| IEC 60320-1 | C14 | Flange Fixing | 2.8/4.8/6.3mm Tabs, Screw Terminal | 10A, 250V AC (15A, 250V AC UL & CSA) | PX0579, PX0580 | Cold Condition, Class I |
| IEC 60320-1 | C14 | Snap fit to Panel | 2.8/4.8/6.3mm Tabs, PC Spills, Screw Terminal | 10A, 250V AC (15A, 250V AC UL & CSA) | PX0575, PX0575/PC | Cold Condition, Class I, Fits Panel Thickness 1-3mm |
| IEC 60320-1 | C14 | Flange Mount | 2.8/4.8/6.3mm Tabs, Screw Terminal, PC Spills | 10A, 250V AC (15A, 250V AC UL & CSA) | PX0580/28, PX0579/28, PX0580/PC | Cold Condition, Class I, Rear Mount Options |
| IEC 60320-1 | C14 | Flange Mount (Fused) | 2.8/4.8/6.3mm Tabs, PC Spills | 10A, 250V AC (Max Fuse Rating 2.5A/10A, 250V AC) | PF0001, PF0002 | Cold Condition, Class I, Single Fuse (5x20mm) |
| IEC 60320-1 | C14 | Snap Fit to Panel (Fused) | 2.8/4.8/6.3mm Tabs, PC Spills | 10A, 250V AC (Max Fuse Rating 2.5A/10A, 250V AC) | PF0011, PF0016 | Cold Condition, Class I, Single Fuse (5x20mm), Fits Panel Thickness 1-3mm |
| IEC 60320-1 | C14 | Flange Mount (Twin Fused) | 2.8/4.8/6.3mm Tabs, PC Spills | 10A, 250V AC (Max Dissipation Per Fuse 2.5W) | PF0030, PF0033 | Cold Condition, Class I, Twin Fuse (5x20mm) |
| IEC 60320-1 | C15 & C16 | Flange Mount | 2.8/6.3mm Tabs, Screw Terminal | 10A, 250V AC (15A, 250V AC UL & CSA) | PX0597 | Hot Condition, Class I |
| IEC 60320-1 | C15 & C16 | Snap Fit to Panel | 2.8/4.8/6.3mm Tabs, Screw Terminal | 10A, 250V AC (15A, 250V AC UL & CSA) | PX0590, PX0595 | Hot Condition, Class I, Fits Panel Thickness 1-3mm |
| IEC 60320-1 | C18 | Flange Mount | 2.8/4.8/6.3mm Tabs, Screw Terminal | 10A, 250V AC (15A, 250V AC UL & CSA) | PX0690 | Cold Condition, Class II (No Earth Plug) |
| IEC 60320-1 | C18 | Snap Fit to Panel | 2.8/4.8/6.3mm Tabs, PC Spills, Screw Terminal | 10A, 250V AC (15A, 250V AC UL & CSA) | PX0691 | Cold Condition, Class II (No Earth Plug), Fits Panel Thickness 1-3mm |
| IEC 60320-1 | C18 | Flange Mount (Fused) | 2.8/4.8/6.3mm Tabs | 10A, 250V AC | PF0006, PF0007 | Cold Condition, Class II (No Earth Plug), Single Fuse (5x20mm) |
| IEC 60320-1 | C18 | Snap Fit to Panel (Fused) | 2.8/4.8/6.3mm Tabs | 10A, 250V AC | PF0016 | Cold Condition, Class II (No Earth Plug), Single Fuse (5x20mm), Fits Panel Thickness 1-3mm |
| IEC 60320-1 | C19 | Cable Mounting | Screw Terminals | 16A, 250V AC (20A, 250V AC UL & cUL) | PX0599 | Cold Condition, Class I, Max Wire Size 3x2.5mm |
| IEC 60320-1 | C20 | Flange Mount | 6.3mm or 4.8mm Tabs | 16A, 250V AC (20A, 250V AC UL & cUL) | PX0596 | Cold Condition, Class I |
| IEC 60320-1 | C20 | Snap Fit to Panel | 6.3mm or 4.8mm Tabs | 16A, 250V AC (20A, 250V AC UL & cUL) | PX0598 | Cold Condition, Class I, Fits Panel Thickness 1-3mm |
| IEC Standard | Sheet No. | Class | Mounting Style | Termination Types | Current Rating | Part Numbers (Examples) | Key Features |
|---|---|---|---|---|---|---|---|
| IEC 60320-2-2 | E | Class I | Cable Mounting | Screw Terminals | 10A, 250V AC | PX0686, PX0686/SE | Rewirable, Straight/Side Entry Male Connector |
| IEC 60320-2-2 | E | Class I | Cable Mounting | Screw Terminals | 10A, 250V AC | PX0685 | Rewirable, Right Angle Male Connector |
| IEC 60320-2-2 | F | Class I | Snap Fit to Panel | 4.8mm Tabs, PC Spills | 10A, 250V AC (15A, 250V AC UL & CSA) | PX0716 | Inlet/Outlet Combination, Fits Panel Thickness 1.2mm |
| IEC 60320-2-2 | F | Class I | Flange Mount | 2.8/4.8/6.3mm Tabs, PC Spills | 10A, 250V AC (15A, 250V AC UL & CSA) | PX0675, PX0675/PC | Outlet |
| IEC 60320-2-2 | F | Class I | Snap Fit to Panel | 2.8/6.3mm Tabs, PC Spills | 10A, 250V AC (15A, 250V AC UL & CSA) | PX0695, PX0695/PC | Outlet |
| IEC 60320-2-2 | F | Class I | Snap Fit to Panel (Shuttered) | 2.8/4.8/6.3mm Tabs | 10A, 250V AC (15A, 250V AC UL & CSA) | PX0783 | Outlet |
| IEC 60320-2-2 | F | Class I | Flange Mount (Shuttered) | 2.8/4.8/6.3mm Tabs | 10A, 250V AC (15A, 250V AC UL & CSA) | PX0793, PX0793/1 | Outlet |
| IEC 60320-2-2 | H | Class II | Flange Mount | 2.8/4.8/6.3mm Tabs | 10A, 250V AC (15A, 250V AC UL & CSA) | PX0705 | Two Plug Class II (No Earth Plug), Outlet |
| IEC 60320-2-2 | H | Class II | Snap Fit to Panel | 2.8/4.8/6.3mm Tabs | 10A, 250V AC (15A, 250V AC UL & CSA) | PX0725 | Two Plug Class II (No Earth Plug), Outlet, Fits Panel Thickness 1-3mm |
| Specification | Value |
|---|---|
| Contact Resistance | <10m (or <15m including Fuseholder) |
| Insulation Resistance | >10 M (or >10 M) |
| A.C. Breakdown (Contact-Contact) | 4kV to 7kV (varies by model) |
| A.C. Breakdown (Contacts-Panel/Accessible) | 4kV to 10kV (varies by model) |
| Operating Temperature | 40C to +70C (or 20C to +70C for some accessories) |
| Max. Plug Temperature | +70C (or +120C for C15/C16) |
| Withdrawal Force | 10N (Min.) to 50N (Max.) |
| Accessory Type | Part Number | Description | Compatible Models (Examples) |
|---|---|---|---|
| Retaining Clip | KT0006 | Prevents accidental removal of connector. Fits flanged inlets. | PX0580 + PX0587, PX0675 + PX0686 |
| Retaining Clip | KT0009 | Prevents accidental removal of connector. Fits fused flanged inlets. | PF0001 + PX0587, PF0030 + PX0587 |
| Retaining Clip | KT0012 | Prevents accidental removal of connector. For use with PX0596 flanged inlet and PX0599 connector. | PX0596 + PX0599 |
| Blanking Cover | PNo 14228 | Protects front of outlet connector. | PX0578, PX0675, PX0695, PX0783, PX0793, PX0716 |
| Insulation Boot | PNo 11328 | Protects rear of connector. | PX0575, PX0579, PX0580, PX0590, PX0595 |
| Insulation Boot | PNo 11987 | Protects rear of connector. | PF range (e.g., PF0001, PF0002) |
| Insulation Boot | PNo 12075 | Protects rear of connector. | PX0675, PX0695, PX0705, PX0725, PX0783, PX0793, PX0793/1 |
| Insulation Boot | PNo 14064 | Protects rear of connector. | PX0596, PX0598 |
| Insulation Boot | PNo 14340 | Protects rear of connector. | PS20, PS21, PS25, PS26 |
| Insulation Boot | PNo 14317 | Protects rear of connector. | PF0030, PF0033 (except /PC versions) |
|
|
Bulgin PF0030/PC Images |